General information

  • Location address
    5 Rue Alphonse Weicker, 2721 Luxembourg
  • Location country
    Luxembourg
  • Year of construction
    1996
  • Function of building
    Shops and stores
  • Degree of enclosure
    Fully enclosed structure
  • Climatic zone
    Temperate - cold winters and mild summers
  • Number of layers
    mono-layer
  • Type of application of the membrane
    covering
  • Primary function of the tensile structure
    • Daylight gains
    • Wind protection

Description

Verification of the calculation, due to problems with the glazing

In 1995 and 1996, an approximately 80 m long shopping arcade was roofed in Kirchberg, Luxembourg. The roof consists of pre-stressed membrane panels and so-called glass eyes in between, lens-shaped panels with overhead glazing. The supporting structure of the glass eyes consisted of steel edge and span beams and was attached to the membrane.
Soon after completion, a series of damages became apparent: the individual panes of glass were wandering around on their supporting structure, several panes of glass were destroyed by cracks and the roof's watertightness was extremely poor.
In the course of the damage investigation, Krätzig & Partner was asked whether the damage that had occurred could be attributed solely to the identifiable defects in the execution or also to possible errors in the static calculation.
The FE calculations carried out by Krätzig & Partner using the in-house developed finite element system FEMAS 2000 essentially confirmed the results of the original structural analysis. In addition, the relative displacements between the glass skin and the supporting structure were calculated, which then formed the basis for the renovation construction.

Description of the environmental conditions

Material of the cover

  • Cable-net/Fabric/Hybrid/Foil
    Fabric
  • Material Fabric/Foil
    Polyester
  • Material coating
    PVC

Main dimensions and form

  • Total length (m)
    80

Duration of use

  • Temporary or permanent structure
    Permanent
  • Design lifespan in years
    21-30

Involved companies

Editor