Garden Exposition Canopy
General information
-
Location address
Paderborn
-
Location country
Germany
-
Year of construction
1993
-
Name of the client/building owner
Landesgartenschau GmbH
-
Function of building
Exhibition
-
Degree of enclosure
Open structure
-
Climatic zone
Temperate - cold winters and mild summers
-
Number of layers
mono-layer
-
Type of application of the membrane
covering
-
Primary function of the tensile structure
- Rain protection
- Space defining elements
- Wind protection
Description
The construction is a prestressed membrane structure, fixed to a supporting structure. The supporting structure consists of poles and tie down cables. Concrete foundations assure the anchorage. Cables are connected to threaded tie rods.
Columns: diam 219,1x5,9; diam 219,1x6,3; diam 323,9x7,1
Length 5,2; 3,2; 11,4m
Inclination 75ᵒ
Steel St 37-2
Concrete B35
Cables 1x37; Steel wire heavy galvanized; E=170kN/mm2
Diam: 30mm
Length: 3,07; 5,07; 11,47m
Membrane thickness 0,9mm; Verseidag PVC-coated polyester type III
Surface 438m2
Snow loading: 0,75kN/m2
Wind loading: -0,65/0,26kN/m2
Prestress edge cable: 51kN; stay cable: 119kN
Prestress membrane: 3kN/m/1,5kN/m
Execution: requires a crane, duration 3 days with 3 persons
Weight: Steel structure 3124kg; cables: 485kg; membrane: 482kg
Cost 48DM (24,5Euro)/m2 for the steel structure; 317DM (162Euro)/m2 for the membrane
Total cost (in 1993): 160 000DM (82 000Euro); maintenance cost 2 000DM (1 000Euro)/year
Description of the environmental conditions
Material of the cover
-
Cable-net/Fabric/Hybrid/Foil
Fabric
-
Material Fabric/Foil
Polyester
-
Material coating
PVC
-
Weight (g/m2)
1000
Main dimensions and form
-
Covered surface (m2)
420
-
Maximum height (m)
6
-
Total length (m)
32
-
Total width (m)
30
-
Form entire structure
Anticlastic
Duration of use
-
Temporary or permanent structure
Permanent
Involved companies
-
Engineers
Ingenieurbüro Teschner GmbH
-
Contractors
Carl Nolte GmbH & Co
Editor
-
Editor
Marijke M. Mollaert