• Copyright Esmery Caron
  • Copyright ARCORA
  • Copyright Esmery Caron
  • Copyright Esmery Caron
  • Copyright Esmery Caron

General information

  • Location address
    Val de Marne
  • Location country
    France
  • Year of construction
    2003
  • Function of building
    Industrial buildings
  • Degree of enclosure
    Fully enclosed structure
  • Climatic zone
    Temperate - cold winters and mild summers
  • Primary function of the tensile structure
    • Rain protection
    • Space defining elements

Description

The ongoing extension works for the treatment plant at the Valenton site (Val de Marne, France), aim at doubling the volume of sewage treated.Ten circular reservoirs are to be covered with metal/textile structures of about 56 meters in diameter and 5.1 meters in height at the fabric summit.The primary metal structure is made out of double chord arches positioned perpendicular to each other. These arches cater for the suspension of a circular top hoop, which acts as a ridge between the two main fabric fields. The textile surface is divided by the circular ridge into two main fields - an outer zone of about 1750 m² shaped as a truncated Chinese hat, and an inner zone of about 750 m² shaped as an impluvium. Both are made from pre-stressed FERRARI fabric 1302 Fluotop T.In addition, specific fabric fields are set to cover the internal circulation pathways and their connections to the main membrane (operculum modules onto bolt cables), as well as to guarantee the closing of maintenance doors and windows (oriel windows and lower skirting).

Description of the environmental conditions

Material of the cover

  • Cable-net/Fabric/Hybrid/Foil
    Fabric
  • Type (code)
    Ferrari 1302 Fluotop T
  • Material Fabric/Foil
    Polyester
  • Material coating
    PVC

Main dimensions and form

  • Covered surface (m2)
    1750
  • Maximum height (m)
    5.1
  • Total length (m)
    56
  • Total width (m)
    56
  • Form single element
    Anticlastic
  • Form entire structure
    Synclastic

Duration of use

  • Temporary or permanent structure
    Permanent
  • Design lifespan in years
    11-20

Involved companies

Editor